Do you ever wonder what the most common EMC failures are so that you can (hopefully) avoid them? Well I do, so I brought together 5 EMC consultants who work hands on with EMC troubleshooting to see what their experiences have been. I asked them to outline what the one or two most common EMC failures are that they’re called in to help out with, and also to give us some tips for ways to avoid them.
Here’s the great advice that they had to give….
Stu Benner
Owner EMConsulting, E3/EMC Design Engineer, iNARTE Certified EMC Engineer
I’m a consultant and most of my work is in the military/aerospace segment. By far the most the most common EMC problem I see is radiated emissions (RE) outages followed closely by conducted emissions (CE) outages.
RE problems are most often caused by poor shield termination techniques or poor printed wiring board (PWB) routing. The root cause of these is often poor design strategy or, should I say, lack of a design strategy. For example, if your strategy is to minimize shielding in your interconnect cabling, you must focus strongly on PWB design to control RE. Alternatively, you can implement an excellent cable shielding design and get away with a little less attention to PWB design. Typically I find there is no strategy other than “just do a little of this or a little of that and we’ll hopefully pass the test.” For designs that must meet strict requirements like the Army Ground requirements of MIL STD 461, good shielding and good PWB design are essential.
A particular RE problem I often see is disregard of lines/signals that carry steady-state or infrequently changing signal such as those that indicate on/off, pass/fail, transmit/receive, or a slow/non-changing analog voltage (called ‘discrete’ inputs/outputs in the mil/aero vernacular), as well as passive interfaces like thermistors. The associated circuits may not generate energy that would cause an RE failure, but that does not mean they are not an EMC problem waiting to happen. You must ensure that such circuits are routed away from noisy signals that could couple energy onto the lines and cause RE problems. These circuits are usually easy to filter heavily with a few simple parts. Remember that in the low state, these signals may effectively couple the circuit signal return (‘ground’) out of the unit. This is likely the lowest impedance common mode noise source in the unit. A similar situation exists when the signals are in the high state and are effectively connected to a voltage supply rail.
The frequent causes of CE problems are poor control of return current paths (particularly common mode current) or poor filter high frequency response due to parasitics. Most power supply designers do a good job of controlling differential mode current and designing filters. Unfortunately, it is often assumed that a low-pass filter’s nearly ideal low and mid frequency response continues upward in frequency. Due primarily to parasitic capacitance, filter attenuation can drop off significantly at higher harmonics of switching frequencies (on the order of several megahertz). Common mode return currents are a bit more insidious. The designer must ensure that there is a low impedance return path for CM current that stays local to the switching element. This requires careful attention to where the currents are generated and where they will flow, remembering that current will always favor the path of lowest impedance. CE problems likely occur if that low impedance path is outside of the unit.
Kenneth Wyatt
Electromagnetic Compatibility (EMC) Consultant and Trainer
As a consultant, primarily working in the industrial, scientific and medical realm, I see radiated emissions as the number one issue. This is followed closely by ESD and radiated susceptibility. The issues causing radiated emissions are just as described by my colleagues above, however, I would add specifically that high speed digital signals crossing gaps in return planes are what keeps the bills paid here.
As for the immunity issues of ESD and radiated susceptibility, I believe these are cropping up more and more largely due to the fact that supply voltages to ICs have been decreasing from 5V to 3.3V to 1.8V to 1.2V, and even lower. Thus, the noise margins are substantially lower than in the past. Couple this with smaller die sizes and the proliferation of wireless, mobile phones, and other high-power communications systems and we’ve greatly increased the risk of interference and circuit disruption from nearby RF fields. The solutions are as described above.
Francesc Daura Luna
The 3 main issues that I encounter are:
#1 Radiated emissions. The solutions that I find usually involve good PCB design and good shielding at box and cable level.
#2 ESD problems. The main solutions for this involve good PCB design, good shielding at box level and using the correct immunity protection components.
#3 Conducted emissions. Main solutions: good PCB and switching power supply design. Correct filtering.
Patrick Andre
President, Principal Consultant at Andre Consulting, Inc.
Most of the problems I find in EMI are based on common mode currents – their sources and the control of them.
It seems common mode currents are created in mysterious ways to many of my clients. There needs to be an understanding that the parasitic properties of components and current routings (wires and traces) are often the source of these currents, or at least the coupling mechanism. For example, a wire or trace with a current on it will induce a magnetic field around it and an electric field from it. If that field is near other wires, traces, or sensitive components, the field can induce a current into it. The noise from the source is now coupled into circuits where it is not intended to go.
Similarly, fields from outside the equipment can couple onto wires or the chassis of the equipment. If not properly controlled, this energy in the form of currents can couple into circuits by these same uncontrolled fields. Understanding these current paths (loops) and being able to control them is much of the foundation of EMC.
Benny Lovan
Systems Integration/EMC Engineer Sr. at Lockheed Martin
I am an EMC Engineer that has worked in a test environment for 9 years. All the information from the previous contributors are great but you could also look at EMI problems and solutions from a test stand point. A good percentage of problems in RE (radiated emissions), as everyone has pointed out, are issues related to test setup. These issues include but are not limited to, shields of cables being less than adequate (due to customers not providing actual cables because of size limitations etc.), bonding of connectors to chassis being well into the 100’s of milliohms if not higher due to rubber (non-EMI) gasketing for moisture purposes or non torqued connections, passing cables through waveguide tubes instead of creating patch panels with bulkhead connectors (support equipment noise couples in really easily with large setups, when using things like signal generators or amplifiers, make sure to take this into account. On the flip side a patch panel will also help when using sensitive measurement devices for data collection during radiated immunity. A scope or analyzer is going to do its job well and show you the transmit signal, so if you’re monitoring your device in the transmit frequency band be sure steps are taken to assure your test setup isn’t causing you to think your device is failing.) and standards knowledge (often times test setups require kluged cables or connectors in order to meet a test setup which may cause unwanted EMI).
All in all, a sit down with your local lab to find out facility requirements and how to optimize your chances of passing or at least a few pre-scans would assist in passing your test during formal scans.
Related Post: Essential EMC Design Rules to Avoid the 7 Most Common EMC Failures
Related Post: How to Do an EMC Design Review
Round-Up
Thanks very much to the contributors of this valuable information. If you want to contribute to the conversation, I’d love it if you could leave a comment below, or if you want to contribute a case study (anonymously), then just tell me about it using this short form here. Everyone benefits from this information, so sharing your experience will help us all to improve our knowledge and skills. If I get more input from EMC consultants or engineers, I may come back and add it to this article, or publish more similar articles.
Comments 15
By far the biggest problem is cabling in RE. Two areas stand out: shield terminations and braid/foil shielding. Need to run shield terminations 360 degrees to a conductive backshell – the pigtail shield termination (and variations thereoff) does not work. Cable shields – either double shielding (braid/insulation/braid) or braid and foil. Ordinary braid – 20 dB SE – braid/braid – 40 dB SE – braid/foil 60 db SE.
Pingback: Essential EMC Design Rules To Avoid The 7 Most Common EMC Failures - EMC FastPass
Agreed with all of the above.
As far as test-setups are concerned: You cannot test a chain with a string, You need a bigger chain: Military equipment cannot be tested by connecting to non-hardened commercial equipment. Properly isolate your verification equipment with fiber-optics/filters etc.
Design:You do not mix colours and whites in washing. Do not mix power/discretes with HF digital or other sensitive sigs in one connector.
Knitted condom: You get that warm feeling, but the long term effects….Always use representative harnesses. It is (not) fine to pass the test with shielded harnesses, even if the installation uses twin flex. The idea is not to pass the test. The idea is to have a system that conforms to the spec in the installation.
Hello all,
I am working on electronics development from last 3 years. I am following layout guidelines and grounding and shielding in my designs.i have gone through many materials. The problem I am facing is not able to understand physics of failures due to emi/emc.
Failure of function due to the noise I understood but if i try it to ask other ways like. I get symptoms of failure. I know the cause that’s it’s a noise which is killing it. And we know solutions in layout or harness.but who is the actual victim I am not able to understand. What things in electronics sub assembly gets affected in what way/ manner to what extent that it fails.
If anyone guide me to this will be very helpful.
Thanks
Author
Hi Rick, visualization of sources and victims falls under understanding how EMC coupling mechanisms work. That is electric (capacitive), magnetic (inductive), conducted and radiated (far field) coupling mechanisms. If you can visualize how these couple to various parts of your circuit and how they induce voltages/currents in susceptible parts then you will be able to work out how your circuit is being negatively affected.
Why is it difficult – if not impossible – to find any consultants who specialize in, or even mention, EMP? I have immediate need for such an expert.
Author
Probably because they’re more rare than an Englishman buying a round at a bar ;). If you want assistance, I offer a service to help find experts in EMC. See emcfastpass.com/jobs for more details.
How are the “mandatory rules” to pass the RF immunity at 100 or 200v/m in anechoic chamber in the 80MHz to 1GHz?
Thank you
Hi all,
We have the 875Mhz and 625Mhz at two point is Fail EN55032 emission standard.
The product is router. It is happen on 1G Wan mode. The system is 25Mhz crystal and it will up to 125Mhz when 1G Wan mode.
Can you help me??
Thanks!!!
BR
Keung
Author
Hi Keung, sent you an email.
Andy.
Hi All,
I have worked with EMC, EMR, EMP, TEMPEST, electrical safety, machinery safety and Radcomms for 40 years. I found that standards are just guidelines and a much better approach is to consider essential protection requirements and to take an engineering approach to design and solving problems. For example I worked on many military projects with a mixture of EMC, EMR and safety standards from different counties. Firstly I wasted a lot of time comparing these standards with one another. Then I worked out that I needed to consider the total environment, mission statement and modes of operation. Once I started taking a view of things outside the requirements of the standards I could focus on the design changes that would be necessary and the modes of operation that would require procedures to prevent problems.
I have worked on the design of ships, trains, factories, buildings and 100s of items of electronic, electrical equipment and 100s of machines. To the best of my knowledge none of these platforms or devices ever had EMC or safety issues. None of the machines went out of control or harmed anyone. None of the military platforms failed to perform their missions.
It is the essential protection requirements that matter and standards just give a presumption of conformity. If I had designed and tested with a standard centric view I would still be redesigning and testing many of the systems to this day. The devices need to be inherently safe and electromagnetically compatible.
Hello folks i am new for this field how can i develop my self in this field.
cold you please any one guide me for my success and our machine not meet standard criteria in Radiated Immunity test now i want to solve the problem.how can i solve this problem.
also other one machine failed in Radiated Emission test in small margin i need your help to solve this both issues.
I wants to know how to solve RI failure of IC AL8400. Any body knows please send me an email. Thank you
I am facing the problem when i connect my controller(equipment) analog output to ac drive.
THe display(16×2 LCd) disturbed and some time malfunctions also. which test will help me to solve this issue?
can you give some hints to solve this issue?
What about Arturo Mediano?