Coaxial RF Current Monitoring Probes – TBCCP1-mx


$889.00$945.00

The TBCCP1-2K70 is a coaxial RF current monitoring probe.
The probe has a very flat response from 2 kHz to 70 MHz and is characterized over the frequency range from 10 Hz to 100 MHz. The TBCCP1-2K80 is designed to be used as transducer for large loop antennas or for applications that need to measure RF currents in coaxial cables. With a trans-impedance of 0 dBΩ, it is compliant with the specifications for large loop antennas (LLA) in CISPR 15 (EN 555015) and CISPR 16-1-4

The TBCCP1-3K100 is a coaxial RF current monitoring probe, expanding the Tekbox product range of affordable EMC pre-compliance test equipment.
The probe has a 3 dB bandwidth from 3 kHz to 100 MHz and a very flat response from 9 kHz to 30 MHz. The transimpedance is characterized over the frequency range from 10 Hz to 100 MHz. The TBCCP1-3K100 is primarily designed for measurement of RF currents in coaxial cables. Furthermore it can be used as transducer for passive loop antennas.
The probe is equipped with N-connectors. An attachment with a ¼” thread permits connectivity to standard tripods.

The TBCCP1-400K600 is a coaxial RF current monitoring probe, expanding the Tekbox product range of affordable EMC pre-compliance test equipment.
The probe has a 3 dB bandwidth from 400 kHz to 600 MHz and a very flat response from 1 MHz to 200 MHz. The transimpedance is characterized over the frequency range from 10 Hz to 100 MHz. The TBCCP1-400K600 is primarily designed for measurement of RF currents in coaxial cables. Furthermore it can be used as transducer for passive loop antennas. The probe is equipped with N-connectors. An attachment with a ¼” thread permits connectivity to standard tripods.

SPECIFICATION

TBCCP1-2K70

  • Characterized frequency range: 10 Hz to 100 MHz
  • Transfer impedance: 0 dBΩ when loaded with 50Ω
  • 3 dB bandwidth: 2 kHz to 70 MHz, typ.
  • Dimensions: 76 mm x 102 x 69 mm
  • Weight: 450 g
  • Connector type: N female
  • Max. primary current (RF): 12 A
  • Max. core temperature: 125 °C

TBCCP1-3K100

  • Characterized frequency range: 10 Hz to 100 MHz
  • Transfer impedance: 5 dB Ohm
  • 3 dB bandwidth: 3 kHz to 100 MHz, typ.
  • Dimensions: 76 mm x 102 x 69 mm
  • Weight: 400 g
  • Connector type: N female
  • Max. primary current (RF): 12 A
  • Max. core temperature: 125 °C

TBCCP1-400K600

  • Characterized frequency range: 10 Hz to 600 MHz
  • Transfer impedance: 23 dB Ohm
  • 3 dB bandwidth: 400 kHz to 600 MHz, typ.
  • Dimensions: 76 mm x 102 x 69 mm
  • Weight: 400 g
  • Connector type: N female
  • Max. primary current (RF): 12 A
  • Max. core temperature: 125 °C

 

SKU: N/A Category: