The TBL0550-1 5µH LISN is a device required to setup conducted noise measurements of DC-powered electronic
equipment. It is designed to be used for measurements in the frequency range of 150kHz to 110 MHz according
to CISPR 16-1-2, CISPR-25, EN55025, MIL-STD-461F, ISO11452-4 and with limitations DO-160/ED-14G and
ISO 7637-2.
The LISN is inserted into the supply line of the DUT (Device Under Test). Conducted noise which is present at
the supply terminals of the DUT can be measured at the BNC connector using a spectrum analyzer or a
measurement receiver. The source (supply) terminal and the DUT terminal are decoupled by a 5µH inductor.
Two TBL0550-1 in combination with the Tekbox LISN Mate enable separate measurements of common mode
and differential mode noise.
The unit comes equipped with a BNC-male to N-male RG232 cable, mating connectors and ground brackets to
attach it to a ground plane.
SPECIFICATIONS
- Frequency range: 100 kHz – 150 MHz
- DC Resistance: < 7 mΩ Source+ to DUT+; < 2 mΩ Source- to DUT-
- Maximum current: 50A continuous, 70 A for 3 minutes
- Nominal operating voltage range: 0 – 60V DC;
- Component rating: 250V
- High current plug/screw terminals – male: Phoenix Contact 1998933, female: Phoenix Contact 1967375
- 1µF capacitor can be disconnected internally by removing a jumper
- Nist traceable calibration data / certificate
- Dimensions: 120 mm x 100 mm x 225 mm (270 mm including ground brackets); weight: 1.6 kg
APPLICATION
- EMC pre-compliance testing of conducted noise